PREIS ANFRAGEN

Mit * gekennzeichnete Felder sind Pflichtfelder.
MRC Global Belgium | Lutz Pompen
Family business since 1954
frederick.lippens@mrcglobal.com
+32 3 633 96 13

Flow meter TS type SL10

for acids, alkalis and aggressive media

Version:

Preis anfragen

Mit * gekennzeichnete Felder sind Pflichtfelder.
  • 0231-011
  • upon request
  • The Flow meter with quantity preselection consists of the parts basic meter (measuring unit) and operating unit (display) and relay module (quantity preselection)
Description: The first flowmeter with touchscreen display and backlight convinces with its...more
Product information "Flow meter TS type SL10"

Version: with Volume preselection (relay module)
Note: The connection to the Pump tube or the system is made with a thread


Description:

The first flowmeter with touchscreen display and backlight convinces with its simple, demand-oriented display and operability, the multilingual interface and the compact design. Due to the rotating swash plate and a magnet, it enables the exact measurement of the volume flow and measures oils, aggressive media such as acids and alkalis precisely, quickly and, above all, efficiently. Optionally, the desired volume can be preselected with a volume preselection (relay module), so that the pump or the system switches off automatically after the selected volume. This further simplifies and secures the operation of the systems.

  • Optional with quantity preselection (relay module)
  • Media examples: Hydrochloric acid, nitric acid, etc.
  • Mobile at a Drum pump or with dispensing gun connection or stationary in the plant construction

Features & Advantages

  • Measurement according to the swash plate principle
  • High measuring accuracy
  • Variable display orientation
  • Touchscreen display with self-explanatory, multilingual user interface
  • Measuring range from 10 l/min- 100 l/min
  • Simple operation
Technische Produktdaten
▼ MEDIUM ▼
Suitable media: Salpetersäure, Salzsäure
▼ WERKSTOFFE | MATERIAL | MATERIAAL ▼
Housing (material): PPO (Polyphenylenether)
Seals (material): FPM (fluorinated rubber)
Measuring chamber (material): PPO (Polyphenylenether), PPS (Polyphenylensulfid)
Magnet: PPS (Polyphenylensulfid) gekapselt
▼ FÖRDERDATEN | OPERATING DATA | SPECIFICATIES ▼
Flow rates (up to l/min): 100
Fluid temperature (max °C): 60
Operating pressure (max. bar): 4
Viscosity (up to mPas): 2000
▼ DURCHFLUSSZÄHLER | FLOW METER | FLOWMETERS ▼
Messprinzip: Taumelscheibe
Connection: Gewinde
Inlet connection (inch): 2"
Outlet connection (inch): 1 1/4"
Messgenauigkeit kalibriert**: ± 1%
▼ EIGENSCHAFTEN | PROPERTIES | EIGENSCHAPPEN ▼
Connection: Gewinde
Voltage (V): 230
Frequency (Hz): 50
Protection type: IP55
Version: with volume preselection
Type: SL10 / RM10 230 V

* The maximum flow rate is a value determined by means of a test bench and measured with water at a medium temperature of approx. 20 °C. The measurement is carried out at the pressure joint of the pump, without hose, nozzle or flow meter. The achievable flow rate in use is lower and depends on the individual application, the liquid properties and the configuration of the pump. The max. delivery head also depends on the pump design, motor and fluid. The viscosity values are determined with oil.

** Test assembly: Medium water / diesel, flow in preferred direction, settling section 0.2 m upstream and downstream of flow meter

Swash plate
Battery
Flow Meter TS type VA10 Flow Meter TS type VA10
for non-flammable liquids
Swash plate
Battery
Flow meter TS type ST10 Flow meter TS type ST10
for mineral oils and low-viscosity media
Service & Support

Sie brauchen Hilfe?

Hier finden Sie alle Möglichkeiten mit uns in Kontakt zu treten:

  +49 9342 879-0 (Zentrale)
  +49 9342 879-260 (Vertrieb)
  +49 9342 879-232 (After-Sales)

  Kontaktformular
  Angebot anfordern
  Reparatur-Service

  info@lutz-pumpen.de
  bewerbung@lutz-pumpen.de