Version: without Volume preselection (relay module)
Note: The connection to the Pump tube or the system is made with a Tri-Clamp connection
Description:
The first flowmeter with touchscreen display and backlight impresses with its simple, on-demand display and operability, multilingual interface and compact design. Thanks to the rotating swash plate and a magnet, it enables the precise measurement of the volume flow and measures aqueous and fatty foodstuffs precisely, quickly and, above all, efficiently. Optionally, the desired volume can be preselected with the volume preselection (relay module), so that the pump or the system switches off automatically after the selected volume. This further simplifies and secures the operation of the systems.
- Optional with quantity preselection (relay module)
- Mobile at a Drum pump or with dispenser connection or stationary in the plant construction
- also for foodstuffs containing alcohol, cosmetics and pharmaceutical products as well as flammable cleaning agents
Features & Advantages
- Measurement according to the swash plate principle
- High measuring accuracy
- Connections suitable for foodstuffs
- Touchscreen display with self-explanatory, multilingual user interface
- Measuring range from 10 l/min- 100 l/min
- Approved according to FDA and regulation (EG) 1935/2004
Housing (material): | Edelstahl (1.4581/1.4571) |
Seals (material): | FEP |
Measuring chamber (material): | Edelstahl (1.4581/1.4571) |
Magnet: | PVDF (Polyvinylidenfluorid) gekapselt |
Flow rates (up to l/min): | 100 |
Fluid temperature (max °C): | 80 |
Operating pressure (max. bar): | from 8 bar |
Viscosity (up to mPas): | 5000 |
Messprinzip: | Taumelscheibe |
Connection: | Tri-Clamp |
Inlet and outlet connection (inch): | Tri-Clamp 32 |
Messgenauigkeit kalibriert**: | ± 1% |
Connection: | Tri-Clamp |
Protection type: | IP55 |
Version: | ohne Mengenvorwahl |
Certification: | FDA-compliant, Verordnung (EG) 1935/2004 |
Type: | VA 10 Pure |
* Die max. Fördermenge ist ein ermittelter Wert mittels Prüfstand und gemessen mit Wasser bei einer Mediumstemperatur von ca. 20° C. Die Messung erfolgt am Druckstutzen der Pumpe, ohne Schlauch, Zapfpistole oder Durchflussmesser. Die im Einsatz erzielbare Fördermenge ist niedriger und hängt von der individuellen Anwendung, den Medieneigenschaften sowie der Konfiguration der Pumpe ab. Die max. Förderhöhe ist ebenso abhängig von Pumpenausführung, Motor und Medium. Die Viskositätswerte werden mit Öl ermittelt. ** Prüfaufbau: Medium Wasser / Diesel, Durchfluss in Vorzugsrichtung, Beruhigungsstrecke 0,2 m vor und nach dem Durchflusszähler